1. Specifications
2. Modulator Specifications
* Symbol Rate: 0.256 – 70 MSPS
* Output Power: 0 to -30dBm in 0.1dB steps
* DVB-S2, SE3™ (QPSK, 8PSK, 16APSK, 32APSK, 64APSK)
* On SE3– 60 different MODCODs
3. Demodulator Specifications
* Symbol Rate: 0.256 – 70 MSPS
* Input Power: -102dBm + 10log(SymbolRate in MSPS) up to -20dBm.
* Data rate: up to 730Mbps on 72MHz TxP
* LNB DC power supply via RX cable 13-18V
4. Networking
* LAN 10/100 for Management interface
* SNMP V1 & V2 support
* RS232 for E1
5. Configuration
* Front Panel Keys
* Web GUI
* RS232 for E1 interface (115200,n,8,1)
6. Front Panel Menus
7. Web GUI
* Three Levels (admin, oper, user)
* Login is needed=> default password is satexpander, which can be modified only by admin.
* Login screen is by pressing the log in tab in the upper menu
8. E1 interface
E1 interface can be accessed using a serial port (115200,n,8,1)
Username is su, password is 1234
9. Menu Structure & Concepts
10. Monitor
– interface – input interface status (which input is connected to which channel and IF speed)
– alarm – alarm screen enable/disable certain alarm
– event – event log
– system – system information (temperature …)
– ACM – return links ACM status from each end point.
– Demodulator – receiver status.
11. Monitor -> Interface->Gig E
12. Monitor -> Demodulator->Line
13. Modulator Config
14. Modulator Config – Line Parameters
15. Modulator Config – Channel Parameters
16. Demodulator Config
17. Demodulator Config- Line Parameters
18. Demodulator Config- Channel Parameters
19. Interfaces Config
20. Duet Config
21. Calculator
About Satxpander Calculator
– The Calculator is an advisor tool that suppose to help users to clearly view different options of system configuration. The Calculator should support the process of choosing the most efficient and desirable configuration settings.
Using the Calculator
– The input of the calculator is one of the following:
● current working modulation DVB-S/S2
● CNR
● SNR
– For each one of the above possible comparison one should state the following requires parameters:
● link-margin
● Roll off
● Pilots On/Off
● Frame Size Normal/Short
● Bandwidth
22. Calculator - Cont
Results
– The calculator will present Mode-Codes that meet the limitations set by the user
– The Calculator also advise the most suitable Mode Code that is expected to provide best results
23. Calculator - Example
24. E1 Operation
25. E1 unframed 2048 (BSC Side)
Next Hop MAC should be taken from other side inventory menu
26. E1 unframed 2048 (BTS Side)
27. E1 framed 2048 (BSC Side)
Press ‘e’ to select all slots
28. E1 framed 2048 (BSC Side)
Next Hop MAC should be taken from other side inventory menu
29. E1 framed 2048 (BTS Side)
Press ‘e’ to select all time slots
30.E1 framed 2048 (BTS Side)
Next Hop MAC should be taken from other side inventory menu
Thank you for your time