PENGUKURAN RETURN LOSS / VSWR


 PENGUKURAN  RETURN LOSS / VSWR

 

1. Alat ukur yang digunakan :

- Power Meter 

- Printer

- Acessories kabel IF  &  RF

- Directonal Coupler  Dual / Single Monitor  RF & IF  Type N Connector

- Directonal Coupler dual / single RF & IF type CPR flange adapter.

- Dummy  load ( IF  / RF )

- Signal Generator  ( IF  s/d RF )

2. Rangkaian pengukuran Return Loss Input.



3. Langkah pengukuran Return loss input:

- Insert Signal to equipment  level power rendah

- Ukur besaran signal dari Monitor input directonal Coupler.( mengukur besaran signal input ) V-in 

- Ukur besaran signal dari monitor output directonal Coupler ( mengukur besaran signal balik dari input perangkat ) V-out reflected


4. Formula Retun Loss : Vinput – Vout Reflected  dB

- Nilai tersebut dapat dikonversikan kedalam VSWR .


5. Data hasil pengukuran :

- Data hasil pengukuran di inputkan dalam FORM terlampir.


6. Rangkaian pengukuran Return Loss Output:

 


7. Langkah pengukuran Return Loss Output :

- Perangkat yang akan diukur tidak boleh di ON kan

- Ukur besaran signal dari Monitor input directonal Coupler.( mengukur besaran signal input ) Vinput

- Ukur besaran signal dari monitor output directonal Coupler ( mengukur besaran signal balik dari output perangkat ) Vout Reflected

- Formula hitungan sama dengan uraian diatas. 

- Nilai tersebut dapat dikonversikan kedalam VSWR .


8. Data hasil pengukuran :

- Data hasil pengukuran dimasukkan dalam form terlampir.